SWITCH INSPECTION SYSTEMS

GENERAL SYSTEM ADVANTAGES

  • Flexible, mobile and reliable, one-person operation. No switch file booking sheets, no reading errors, but increased measuring accuracy and directly measurable values as well as their systematic capture, evaluation and storage... This is the latest version of switch measuring systems. It has been optimized on the basis of the knowledge, expirience and needs of its users...
  • bullet    Software, measurement electronics and the measuring device itslef have been purpose-designed as a single integrated system. All components thus form a unified whole so interface problems are eliminated. A long measurement base allows direct measurement even across gaps, especially at obtuse crossings.
  • bullet    Opto-electronic sensors eliminate reading errors and inaccuracy due to parallax. PTP is resistant to any electromagnetic effects and can be used in any weather.

4 COMPONENTS 1 SYSTEM

  • Display showing measurement positions and a simple membrane keypad for storing the measured values. Memory for 3000 measurements or 60 switches ( per memory module). Request and execution of a detailed multistage check list covering a variety of menu items. Display can be rotated through 180°.
  •  Digital basic measuring device with opto- electronic sensors, sliding clutch for defined
  • Rolling adaptor trolley as a platform for the basic measuring device and for transfer
  • Software handles all switch and crossing data listed in switch file sheets. Master switch data : the number of measurements is unlimited. Two bitmabs plus textual information may be stored for each type of switch. Multi-stage check list for qualitative check on switches under the following heads: measuring position, technical detail, condition, size/number, maintenance recommendations

 

The switches to be inspected are compiled into one worksheet by means of the Profi software. The PC then loads the worksheet into the memory module. The display of the measuring device shows information on switch number, switch type, measuring position etc., together with the measurments themselves. The user-friendly menu offers a free choice from among the switches stored. It suggests the order of measurments within the switch, highlights the measurments carried out and indicates the measurments yet to be made. It allows the selection or input of structural defects from a pre-defined, multi-stage check list. All measurments and records of defects are stored in the memory module. After switch inspection, the data gathered in the memory module is passed to the PC and may be edited on screen or printed out. The memory module is then available for reloading. The inspection results obtained at pre-defined intervals are added to the switch history which thus provides a record of the whole life of the switch. The switch maintenance requirements and spare parts needed, together with their costs, can be included in the switch history which thus allows a technical and financial review of switches at any time.

TECHNICAL SPECIFICATIONS:

  • DIGITAL BASIC MEASURING DEVICE: microprocessor - controlled, four - line LCD (2.9 X 0.9 inches, illuminated), opto - electronic sensor - resolution: 0.003937 inch, weight: 6.6 lb
  • MEMORY MODULE: Storage capacity: 3000 measurements or 60 switches, 2 NIMH batteries-operation time: 25 hours, weight: 7.7 ounces, dimensiones: 2.9 X 2.6 X 1.2 inches
  • SOFTWARE: for all switches and diamond crossings (with or without slip), for all gauges, freely prgrammable measurement points, theoretical values and tolerances, four stage checklist, switch history, Windows 2000, NT 4.0 and XP (Standard delivery package: CD, handbook)
  • SWITCH CADDY: operation level 28.7 inches above top of rail, insulated, weight: 53 lb.

 

measa4

Data can be imported and exported via docking station and takes no longer than two minutes, even for a full memory

measa5

Easy setup memory module with basic device. The measuring device can communicate with a PDA or a PC via an RS 232 interface.

 